Versatile. Long lasting. Low fuming.
In creating PermaMop® modified roofing asphalt, we didnt just one-up regular asphalts, weve three-upped them.
PermaMop is versatile. Its specially formulated for use on any slope of roof. It has the softening point of a Type IV asphalt but with a lower equiviscous temperature (EVT) than any standard Type IV. It stays where its mopped, even on steep-sloped roofing in intense heat.
PermaMop is long lasting. In laboratory testing, ordinary asphalt exceeds 60 weather cycles (approximately 15 years). PermaMop lasts a minimum of 150% longer withstanding up to 193 cycles. Making it an ideal choice for projects in extreme weather areas whether its heat, cold or moisture.
PermaMop is low fuming. Its composition includes a technologically advanced polymer additive. When heated, the polymer floats to the surface and creates a skim layer on the kettle that traps the fumes and odor inside without affecting the asphalt or disrupting kettle operation.
PermaMop. Just another example of how Trumbull is using Applied Innovation to create products that solve our customers biggest needs.
PermaMop® Modified Asphalt Brochure
PermaMop® MSDS Sheet |
| Features |
Benefits |
| All products meet ASTM D312 |
Each shipment meets or exceeds the physical requirements of the specified roofing grade asphalt |
|
| Consistent high flash material |
Proper temperature range needed to apply product safely at the EVT; flash points typically 50ºF to 75ºF higher than the 500ºF minimum |
|
| Testing in each plant and at Summit, IL laboratory |
All Owens Corning Trumbull products are assured to meet ASTM requirements |
|
| 19 producing plants |
Convenient, accessible availability from coast to coast |
|
| EVT shown on each carton and bill of lading for bulk shipments |
Assures proper adhesion, waterproofing and application rate |
|
| Printed cartons |
Clearly identifies manufacturers, type, flash point, EVT, production location and production date |
Physical Requirements - ASTM D312-00
| |
Type I |
Type II |
Type III |
Type IV |
Test Methods |
| |
Min. |
Max. |
Min. |
Max. |
Min. |
Max. |
Min. |
Max. |
| Softening Point (ºF) |
135 |
151 |
158 |
176 |
185 |
205 |
210 |
225 |
ASTM D36 |
|
| Flash Point (ºF) |
500 |
|
500 |
|
500 |
|
500 |
|
ASTM D92 |
|
| Penetration, Units, dmm: |
| @32ºF |
3 |
|
6 |
|
6 |
|
6 |
|
ASTM D5 |
| @77ºF |
18 |
60 |
18 |
40 |
15 |
35 |
12 |
25 |
|
| @115ºF |
90 |
180 |
|
100 |
|
90 |
|
75 |
|
|
| Ductility @77ºF, cm |
10.0 |
|
3.0 |
|
2.5 |
|
1.5 |
|
ASTM D113 |
|
| Solubility in Trichoroethylene % |
99 |
|
99 |
|
99 |
|
99 |
|
ASTM D2042 |
|
| Asphalts shall be homogenous and free of water and shall conform to these physical properties |
Typical Physical Characteristics for Trumbull Asphalt
| |
PermaMop |
|
| Softening Point (ºF) |
215-235 |
|
|
| Flash Point (ºF) |
525 |
|
|
| Penetration, Units, dmm: |
| @32ºF |
7 |
|
| @77ºF |
18 |
|
|
| Ductility @77ºF, cm |
7.0 |
|
|
| Solubility in Trichoroethylene % |
97.5 |
|
|
| Typical Application Temperature |
|
|
| For Hand Mopping |
|
|
| EVT @125 CPS +/- 25ºF |
375 |
|
| For Machine Spreader |
|
|
| EVT @ 75 CPS +/- 25ºF |
395 |
|
|
| Plant Specific EVTs |
|
|